BYDSH - F-124 CHAMPAGNE 144 DOD-E-24607A, F-15P36
- MSDS: BYDSH
- Manufacturer: SEAGRAVE COATINGS CORP OF VA
- Product Name: F-124 CHAMPAGNE 144 DOD-E-24607A, F-15P36
- National Stock Number: 8010-00N061414
Product Identification
Product ID:F-124 CHAMPAGNE 144 DOD-E-24607A, F-15P36
MSDS Date:08/05/1994
FSC:8010
NIIN:00N061414
MSDS Number: BYDSH
Responsible Party
PORTSMOUTH, VA 23701-2636
US
Emergency Phone: 804-488-4411
Info Phone: 804-488-4411
Cage: 60163
Contractor
Telephone: 757-397-2223
Cage: 60163
Ingredients
TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 25%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
BARIUM SULFATE; (BARYTES)
CAS: 7727-43-7
RTECS: CR0600000
Fraction By Weight: 40%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
STODDARD SOLVENT; (MINERAL SPIRIT)
CAS: 8052-41-3
RTECS: WJ8925000
Fraction By Weight: 20%
OSHA PEL 500 PPM
ACGIH TLV: 100 PPM
1 @ 20C.
CAS: 64742-94-5
RTECS: WF3100000
Fraction By Weight: 5%
OSHA PEL N/K
ACGIH TLV: 10 PPM (MFR)
3.17 LG/GAL (380 G/L).
RTECS: 9999999VO
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:BREATHING OF HIGH VAPOR CONCENTRATIONS
MAY PRODUCE NARCOSIS. LIQUID MAY CAUSE MINOR SKIN IRRITATION &
DEFINITE EYE IRRITATION. CAUSES EYE/SKIN IRRITATION. REPEATED &
PROLONGED OVEREXPOSURE TO SOLVENTS COULD CAUSE PERMANENT BRAIN &
NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE BY DELIBERATELY
CONCENTRATING (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:& INHALING CONTENTS MAY BE HARMFUL OR
FATAL.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR, RESTORE BREATHING. CONSULT MD.
SKIN:WASH THOROUGHLY W/SOAP & WATER. EYE:FLUSH IMMEDIATELY W/LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES & GET IMMEDIATE MEDICAL
ATTENTION. INGEST:GET MEDICAL ATTENTION IMMEDIATELY.
Fire Fighting
Flash Point Method:SCC
Flash Point:100F,38C
Lower Limits:1.8%
Upper Limits:17.8%
Extinguishing Media:WATER FOG, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WATER MAY BE USED TO COOL CONTAINERS. IF WATER IS USED
FOG NOZZLES ARE PREFERRED.
Unusual Fire/Explosion Hazard:FLAMM LIQ - CLASS III. KEEP CNTNRS
TIGHTLY CLSD. VAPS MAY MIGRATE TO IGNIT SOURCE & CAUSE FLASH FIRE.
ISOLATE FROM HEAT, SPKS, ELEC EQUIP, APPLIANCES, (SUPDAT)
Accidental Release
Spill Release Procedures:IN CASE OF SPILLAGE ABSORB W/INERT MATERIAL &
DISPOSE OF I/A/W APPLICABLE REGULATIONS OF EPA & OTHER LOCAL, STATE
& FEDERAL AUTHORITIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE AWAY FROM HEAT, SPARKS & OPEN
FLAME. AVOID PROLONGED SKIN CONTACT. DO NOT BREATHE SPRAY MIST.
AVOID CONTACT W/EYES, SKIN & CLOTHING.
Other Precautions:STORE IN A COOL, DRY AREA W/VENT SUITABLE FOR STORING
MATERIALS SHOWN IN INGREDIENTS SECTION. GROUND CNTNRS WHILE
POURING. AVOID SPONT COMBUST OF CONTAM RAGS/OTHER ORGANIC MATLS.
EMPTY CNTNRS MAY RETA IN HAZ PROPERTIES & CAN BE DANGEROUS.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPRVD RESP TYPES SUITABLE FOR INGS
REC. NIOSH/MSHA APPRVD CHEM/MECH FILTERS REC WHEN VENT IS
RESTRICTED. DO NOT BREATHE (DUST, VAPS/SPRAY MIST). WEAR APPROP
NIOSH/MSHA APPRVD RESP DURING & AFTER APPLICATION UNLESS AIR
(SUPDAT)
Ventilation:SUFFICIENT VENT, IN VOL & PATTERN, SHOULD BE PROVIDED TO
KEEP AIR CONTAM BELOW CURRENT APPLIC OSHA PEL/ACGIH'S (SUPDAT)
Protective Gloves:CHEMICAL RESIST PLASTIC/RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:AS REQD TO AVOID WETTING CLTHG. USE PROT
CREAMS WHERE SKIN CONT IS LIKELY. EMERG EYE WASH & DELUGE SHOWER
(SUP DAT)
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. REMOVE & WASH
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
EXPLO HAZ:PILOT LIGHTS, FLAMES & OTHER SOURCES OF IGNIT. COMBUST LIQ &
VAP. RESP PROT:MONITORING RECORDS VAP/MIST LEVELS BELOW APPLIC
LIMS. FOLLOW RESP MFR DIRECTIONS FOR USE. VENT:TLV LIM. USE W/ADEQ
VENT. EYE PROT:& FULL LENGTH FACESHIELD . OTHER PROT EQUIP:WHICH
MEET ANSI DESIGN CRITERIA .
Chemical Properties
Boiling Pt:B.P. Text:>315F,>157C
Vapor Pres:SEE ING 4
Vapor Density:HVR/AIR
Spec Gravity:1.75
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:INSOLUBLE
Appearance and Odor:LIQUID; SOLVENT ODOR.
Percent Volatiles by Volume:45.1
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXCESSIVE HEAT, SPARKS OR OPEN FLAME.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:PLACE IN CLOSED CONTAINERS. DISPOSE OF PRODUCT
I/A/W LOCAL, COUNTY, STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.